Add to Cart
Proline Promag P300,5P3B Electromagnetic Flow Meter
Product description
High temperature resistant flowmeter with easy to operate integrated transmitter for a variety of process applications.
Promag P sensors are designed for the measurement of high temperature and corrosive media in chemical and process applications. Used with an integrated transmitter, the Promag P 300 offers flexibility and easy system integration: wiring on the same side of the meter, remote display, improved connectivity. Heartbeat Technology ensures consistent compliance and process safety.
advantage
Wide range of applications: a variety of welding parts materials available
Energy efficient flow measurement: no throttling components to ensure no pressure loss
Maintenance-free: no moving parts
Complete view of process and diagnostic information: Multiple user-defined input/output combinations and fieldbuses are available
Reduce complexity and variety: User-defined input/output functions
Built-in verification function: Built-in Heartbeat Technology
Application field
The bidirectional measurement principle is not affected by pressure, density, temperature and viscosity
Special flow meter for the measurement of high temperature and corrosive media in chemical and process applications
Instrument characteristics
Nominal diameter: max.DN 600 (24")
All General Explosion-proof (Ex) certifications
PTFE or PFA lining
Integrated double chamber exterior shell, *** with 3 input/output
Backlit display, touch key control and WLAN access
Separate display unit available
Features and specifications
Product title
Temperature rated flowmeter with easy to operate integrated transmitter. Special flow meter for the measurement of high temperature and corrosive media in chemical and process applications.
Sensor characteristics
Wide application: Provide a variety of liquid parts materials. Energy efficient flow measurement: no other devices in the pipe, no pressure loss. Maintenance-free: no moving parts. *** Large nominal caliber: DN 600 (24"). All general explosion-proof certifications.
Transmitter features
Provides complete process and diagnostic information: a variety of user-generated I/O interfaces and fieldbuses. Reduce complexity and variety: Allow users to customize input/output functions. Self-verification: Heartbeat Technology. Compact dual-chamber exterior housing, *** allows connection of up to 3 inputs/outputs. Backlit display, touch key operation and WLAN access.
Nominal caliber range
DN 15... 600 (½...) 24 ")
Material of liquid parts
Lining: PFA, PTFE
Electrode: 1.4435 (316L), Alloy C22, 2.4602 (UNS N06022) alloy, tantalum, platinum,
Titanium, Duplex Steel Duplex 1.4462 (UNS S31803)
Measured variable
Volume flow, conductivity, mass flow
*** Large measurement error
Volume flow rate (standard) : ± 0.5%o.r. ± 1mm /s (0.04 in/s)
Volume flow rate (optional) : ± 0.2% o.r. ± 2 mm/s (0.08 in/s)
Measuring range
4 dm³... 9600 m³/h (1... 44 000 gal/min)
*** High process pressure
PN 40, Cl.300, 20K
Medium temperature range
PFA lining: -20... +150 °C (–4... +302 °F)
High temperature PFA lining: -20... +180 °C (–4... +356 °F)
PTFE lining: -40... +130 °C (–40... +266 °F)
Ambient temperature range
Carbon steel flange: -10... +60 °C (+14... +140 °F)
Stainless steel flange: -40... +60 °C (–40... +140 °F)
Sensor housing material
DN 15... 300 (½... 12") : Aluminum alloy AlSi10Mg coating
DN 350... 600 (14...) 24") : carbon steel with bedliner coating
Transmitter housing material
With aluminum alloy AlSi10Mg coating: 1.4409 (CF3M), similar to 316L; Stainless steel or sanitary transmitter housing
Class of protection
Standard: IP66/67, Type 4X
Optional: IP69
Display/operation
Four-line backlit display, touch key operation (external operation)
Through the on-site display and debugging software Settings
Separate display unit available
exportation
3 outputs:
4... 20 mA HART (Active/passive)
4... 20 mA WirelessHART
4... 20 mA (Active/passive)
Pulse/frequency/switching output (active/passive)
Dual pulse output (active/passive)
Relay output
input
Status input
4... 20 mA input
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
Power source
24 VDC
100... 230 VAC
100... 230 VAC / 24 VDC (non-hazardous area)